Real Time Knock Graph (locked mode)
rpm:
The actual engine rpm
lvl:
The actual signal level from the knock sensor
thr:
Knock threshold value for current rpm, if exceeded then knock is detected
cnt:
Shows the number of detected knock events. Can be reset by pressing the "UP" button
Hint!
To reset all displayed data press "UP" and "DOWN" keys together .
Knock Level Log Graph (edit mode)
rpm:
The engine rpm at the cursor position
lvl:
The recorded signal level at the cursor position
thr:
The knock threshold value for the current cursor position
cnt:
Displays the recorded number of knock events at the current cursor position.
Hint!
Move cursor with LEFT and RIGHT keys. Adjust knock threshold with UP and DOWN keys.
Press UP and DOWN keys together to automatically adjust the knock threshold curve after
having logged the base engine noise profile.