QUICK INFO
A new control option for time based boost control has been added in firmware version 1.16. This control option is mostly suitable for tuning traction in drag racing applications.
CONFIGURATION
- Enable the "time control" option for your desired preset in menu 4.2.
- If you want to trigger the time start from a clutch switch or other external switch select "CLUTCH" or "CLUTCH INV" in menu 5.7 according to your switch input polarity.
- When the Switch status is OFF time will remain at 0. When the Switch status changes to ON time will start counting up until it reaches 7.5sec where it will remain until the switch is reset to OFF again.
- If you want to trigger the time start with vehicle speed then the settings in menu 5.7 must not be "CLUTCH" or "CLUTCH INV".
- Time will start counting up as soon as the vehicle speed is above zero until it reaches 7.5sec. It will reset to zero when the vehicle stops.
- Corrections of either duty or boost target can be configured in menus 2.8(open loop) and 3.8(closed loop).
- Interpolation is used between the 0.5sec corrections points so large step changes in duty or boost target can be used if needed.
- IMPORTANT: When time exceeds 7.5 seconds the last correction will continue to apply until time is reset to 0.